Artikkelinumero | Selvennys |
667001 | Liquid filter 667-UV1 Liquid filter type 667-UV1 for testing stray light according to Ph. Eur., content: Potassium chloride in pure water, light path 10 mm,... |
105516677 | Liquid filter set 667-UV003 Liquid filter set type 667-UV003 for checking UV/Vis spectrometers according Ph. Eur., consisting of 8 liquid filters: Testing... |
105516678 | Liquid filter 667-UV5 Liquid filter type 667-UV5 for checking wavelength accuracy according Ph. Eur., content Holmium in perchloric acid, certified at... |
667006 | Liquid filter 667-UV6 Liquid filter type 667-UV6 for testing the resolution according to Ph. Eur. and USP 857, content: Toluene in hexane, certified at... |
667009 | Liquid filter 667-UV9 Liquid filter type 667-UV9 reference filter for testing the resolution according to USP 857, content: Hexane, in high quality storage box |
667010 | Liquid filter 667-UV10 Liquid filter type 667-UV10 for testing stray light, content: Sodium iodide in pure water, light path 10 mm, certified at wavelength:... |
667011 | Liquid filter 667-UV11 Liquid filter type 667-UV11 for testing stray light, content: Sodium nitrite in pure water, light path 10 mm, wavelength: 385 nm... |
667012 | Liquid filter 667-UV12 Liquid filter type 667-UV12 reference filter for testing stray light according to Ph. Eur., content: pure water, light path 10 mm,... |
667014 | Liquid filter 667-UV14 Liquid filter type 667-UV14 reference filter for testing photometric accuracy according to Ph. Eur., content: Perchloric acid (HClO4),... |
667019 | Liquid filter 667-UV19 Liquid filter type 667-UV19 for testing stray light, content: Acetone, light path 10 mm, certified at wavelength: 325 nm (cut-off), in... |
667020 | Liquid filter 667-UV20 Liquid filter type 667-UV020 for testing the photometric accuracy, content: 20 mg/l Potassium dichromate in perchloric acid,... |
667023 | Liquid filter 667-UV23 Liquid filter type 667-UV23 for testing stray light, content: Potassium iodide in pure water, light path 10 mm, certified at... |
667025 | Liquid filter 667-UV25 Liquid filter type 667-UV25 for checking wavelength accuracy, content: Didymium in perchloric acid, certified at wavelengths: 329;... |
6670100 | Liquid filter 667-UV0100 Liquid filter type 667-UV0100 for testing the photometric accuracy, content: 100 mg/l Potassium dichromate in perchloric acid,... |
6670120 | Liquid filter 667-UV0120 Liquid filter type 667-UV0120 for testing the photometric accuracy, content: 120 mg/l Potassium dichromate in perchloric acid,... |
6670140 | Liquid filter 667-UV0140 Liquid filter type 667-UV0140 for testing the photometric accuracy, content: 140 mg/l Potassium dichromate in perchloric acid,... |
6670160 | Liquid filter 667-UV0160 Liquid filter type 667-UV0160 for testing the photometric accuracy, content: 160 mg/l Potassium dichromate in perchloric acid,... |
6670180 | Liquid filter 667-UV0180 Liquid filter type 667-UV0180 for testing the photometric accuracy, content: 180 mg/l Potassium dichromate in perchloric acid,... |
6670200 | Liquid filter 667-UV0200 Liquid filter type 667-UV0200 for testing the photometric accuracy, content: 200 mg/l Potassium dichromate in perchloric acid,... |
667001H | Liquid filter 667-UV1H Liquid filter type 667-UV1H for testing stray light, reference filter according to USP 857, content: Potassium chloride in pure water,... |
667005USP | Liquid filter 667-UV5USP Liquid filter type 667-UV5USP for testing wavelength accuracy according USP 857, content: Holmium in perchloric acid, certified at... |
667010H | Liquid filter type 667-UV10H for testing stray light, reference filter according Liquid filter type 667-UV10H for testing stray light, reference filter... |
667011H | Liquid filter type 667-UV11H for testing stray light, reference filter according Liquid filter type 667-UV11H for testing stray light, reference filter... |
667019H | Liquid filter 667-UV19H Liquid filter type 667-UV19H for testing stray light, reference filter according to USP 857, content: Acetone, light path 5 mm,... |
667025EPUSP | Liquid filter 667-UV25EPUSP Liquid filter type 667-UV25USP for testing wavelength accuracy according Ph. Eur. And USP 857, content: Didymium in perchloric... |